Implant

01

IT

Root Form & Progressive Power Thread

img

It has a tapered body design of root form as a whole. The Progressive Power Thread that gets deepen from 2° to 4° of lower apex has not only the excellent initial fixation, but also effective stress dispersion instigated by the square shape.

Micro Thread

img

400μm of Micro Thread has the effect of increasing the second stability and dispersing the stress by increasing the bone density and widening the surface area in the marginal bone.

Narrow Neck & Microgroove

img

Abutment is forming a narrow neck with a curved concave profile design, and 50µm of microgroove on the lower side has the effect that the connective tissue adheres well. It forms a stable and thick connective tissue and is very effective for soft integration tissue.

SLA(ABE) Surface

Warantec’s SLA (ABE-Advanced Blasting & Etching) surface has the most ideal RA (Roughness) value of 1.44μm. It has round and uniform surface texture and has less sharp parts.

  • img

    X500

  • img

    X1,000

  • img

    X5,000

  • img

    X10,000

7° Internal Octagonal Connection

img

IT implant system has robust friction attachment of 7 degrees, so that minimizes the abutment’s movement even though the screw loosens, therefore it blocks the bone loss excellently. Also, it has the Octa Connection, so that gives an advantage for the directionality of the prosthetic.

FL Design

img

The FL design of IT implant system protects the upper part of abutment attaching area of the inside of the Fixture that has robust friction until attaching the final prosthetic, and can reduce the error of vertical subsidence that originated from the friction fit of the internal connection implants.

02

OIT

Onebody Implant

img

External connection and Internal connection implants have the possibility of micro movement, and this can instigate the screw loosening and bone loss. Warantec’s Onebody IT implant system is a non-connection integral implant system with the original design that has resolved these factors completely.

03

HT

Long Hex Top & Dual Hex-fit

img

HT implant system has external hex connection. Compare to the existing hex top, HT implant has the height of 1mm, so that reduces the complication such as screw looseness instigated by the external connection dramatically. Also, by applying the dual hex-fit design, it has an advantage for the directionality of the prosthetic on the angled abutment.

01

IU

Safer Stress Point

img

IU implant system has the design which the straight thread angle and tapered body shape are properly combined. By placing the compression point 3mm under the cortical bone (subcortical area), the system can suppress the bone resorption of the cortical bone. Also, by applying the square thread on the upper part of the fixture (cortical & subcortical area), the system can obtain great initial fixation even on the soft quality bone, and can decrease the maximum Von Mises Stress on the cortical bone.

Easy Implantation with V Shape Thread

img

The self-tapping V shaped thread and the increasing thread depth on the apical area can make the convenient implantation and stable fixation power.

11° Internal Hex Connection

img

IU implant system has 11 degrees of Internal Hex Connection.

02

OIU

Onebody Implant

img

External connection and Internal connection implants have the possibility of micro movement, and this can instigate the screw loosening and bone loss. Warantec’s Onebody IU implant system is a non-connection integral implant system with the new design that has resolved these factors completely.

01

UT

Root Form & Progressive Power Thread

img

It has a tapered body design of root form as a whole. The Progressive Power Thread that gets deepen from 2° to 4° of lower apex has not only the excellent initial fixation, but also effective stress dispersion instigated by the square shape.

Micro Thread

img

400μm of Micro Thread has the effect of increasing the second stability and dispersing the stress by increasing the bone density and widening the surface area in the marginal bone.

SLA(ABE) Surface

Warantec’s SLA (ABE-Advanced Blasting & Etching) surface has the most ideal RA (Roughness) value of 1.44μm. It has round and uniform surface texture and has less sharp parts.

  • img

    X500

  • img

    X1,000

  • img

    X5,000

  • img

    X10,000

11° Internal Hex Connection

img

UT implant system has 11 degrees of Internal Hex Connection.

01

EZi

img
  • Easy & Simple Narrow Implant

    - Onebody type mini implant suitable for narrow ridge and mandibular anterior
    - Available in a wide range of clinical cases, from single to denture
    - Easy and intuitive surgical procedures
    - Excellent initial fixation through root form shape and self-tapping groove

  • Friction – Lock Connect

    Applied the Friction-Lock technology on the upper part of the Onebody connection so that it can connect the abutment without cement, and provide easier surgery without the concern for remaining cement. It can be applied to the various clinical cases such as Flapless Surgery, dental restoration for narrow interproximal space, temporary implant, and etc.

01

InEx

InEx Prosthetics chart
IT IU Impression Milling & SB & CCM Analog Scan body TI-base Custom Abut
Lab
Analog
Digital
Analog
Hex Non-Hex Hex Partial
Hex

Screw Included

SB

IC0MAN40H

MUDAN40

MUSCT40

MUTB45SH

MUTB45TN

Screw Included

Milling
SB
CCM

IC0MAN43H

MUDAN50

MUSCT50

MUTB55T

MUTB55TL

SUSB55H

IC0SAN50H

SUDAN50

SUTB58SH